Technical Specifications:
SC5020F | SC7020F | |
---|---|---|
Chassis Overview | ||
Chassis format | All-in-one (dual controllers, internal drive bays, networking) with expansion options | |
Rack size | 3U | 3U |
Controllers | 2 hot-swappable per chassis (active/active) | |
Processors | Single Intel Xeon Processor E5-2630 v3, 2.4GHz, 8 cores | Dual Intel Xeon Processors, E5-2628 v3 2.5GHz, 8 cores |
Internal storage capacity | 30 x 2.5” drive bays | |
System memory | 128GB per array (64GB per controller) | 256GB per array (128GB per controller) |
Operating system | Dell Storage Center OS (SCOS) 7.2 or greater | Dell Storage Center OS (SCOS) 7.2 or greater |
Expansion Capacity | ||
Max raw capacity | 2.16PB per array, more in federated systems | 4PB per array, more in federated systems |
Maximum drive count | 222 per array (with optional expansion enclosures), more in federated systems | 606 drives per array, more in federated systems |
Supported expansion enclosures | 12Gb SAS SC400: 12 x 3.5” bays SC420: 24 x 2.5” bays SC460: 60 x 3.5” bays |
12Gb SAS SC400: 12 x 3.5” bays SC420: 24 x 2.5” bays SC460: 60 x 3.5” bays |
Storage media support | SSD: write-intensive and read-intensive drives (can be mixed in single system), SED SSDs | |
Network and Expansion I/O | ||
Front-end-network protocols | FC, iSCSI (supports simultaneous multiprotocol) | |
Max 32Gb FC ports | 8 per array (SFP+) | 24 per array (SFP+) |
Max 16/8Gb FC ports | 8 per array (SFP+) | 24 per array (SFP+) |
Max 100Gb iSCSI ports | 8 per array (SFP28) | 16 per array (SFP28) |
Max 25Gb iSCSI ports | 8 per array (SFP28) | 16 per array (SFP28) |
Max 10Gb/1Gb iSCSI ports | Up to 16 SFP+ (10Gb) or Base-T ports per array | Up to 32 SFP+ (10Gb) or Base-T ports per array |
Management ports | 2 per array (1Gb BASE-T) | |
Back-end expansion protocols | 12Gb SAS | |
Max back-end expansion ports | 8 per array | 24 per array |
SC5020F | SC7020F | |
Functional & Performance | ||
Array configurations | All-flash arrays only | |
Storage format | Native block (SAN) | |
Max SAN hosts | 500 | 500 |
Max initiator ports | 1000 | 1000 |
Max LUN size | 500TB | 500TB |
Max number of LUNs | 2000 | 2000 |
Max number of snapshots | 8,192 | 16,384 |
Max IOPS | 1,025,000 | 1,200,000 |
Max IOPS (with latency <1ms) | 818,000 | 1,050,000 |
Max IOPS (80% reads, 20% writes) | 330,000 | 346,000 |
Max throughput (reads) | 19,000 MB/s | 29,000 MB/s |
Max throughput (writes) | 9,500 MB/s | 14,000 MB/s |
Data Optimization | ||
Auto-tiering method | Policy-based migration based on real-time data usage, customizable 512KB-4MB page size. | |
Auto-tiering structure | Up to 2 SSD tiers (write- and read-intensive SSDs) | |
Tiering customizations | User-defined profiles, option to “pin” volumes to any tier | |
RAID support | RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist in single array | |
RAID tiering | Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups | |
Thin provisioning | Active by default on all volumes, operates at full performance across all features | |
Thin snapshots | Records changes only, snapshots auto-migrate to lower-cost storage | |
Intelligent deduplication and compression | Selectable option per volume “Deduplication + Compression” and “Compression only” modes available | |
Data Mobility and Migration | ||
Replication | Heterogeneous arrays (SC Series any-to-any) Synchronous/Asynchronous via FC or iSCSI Target/source relationships may be one-to-many or many-to-one Supports all SC data services on source and target volumes Change replication types and topologies on demand Supports cross-platform replication with PS Series/EqualLogic arrays (either direction) |
|
Volume mobility | Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section | |
Federated multi-array systems | Live Migrate (included in base product) enables host-transparent movement of volumes among arrays Snapshots maintained/preserved during migration | |
Thin Import | Space-efficient, non-disruptive data migration from PS Series (EqualLogic) and MD3 arrays | |
Thin Clones | Clone standalone volumes with zero duplication of data Clones maintain independent snapshots and replication Ideal for VDI, test/dev, other applications that require discrete instances of common data More efficient than dedupe for database copies |
|
Data Protection, Disaster Recovery, Security | ||
Business continuity | Live Volume bi-directional auto-failover, auto-repair Heterogeneous arrays (SC Series any-to-any, except SCv2000) Continuous operations, disaster recovery, disaster avoidance Includes third-site (tertiary) replication options with Live Volume Managed Replication Zero RTO/RPO with customizable site failover SLAs per volume Does not require identical hardware at each site VMware Metro Stretch Cluster, VMware Site Recovery Manager support |
|
Thin snapshots | Records changes only, snapshots auto-migrate to lower-cost storage | |
Replay Manager | Application-consistent snapshots in Microsoft, VMware, Oracle environments | |
Data-at-rest encryption | Supports self-encrypting drives (SEDs) Full Disk Encryption (FCE) based on AES-256 Drives certified to FIPS 140-2 Level 2 Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3 |
|
External key manager support | Gemalto’s SafeNet KeySecure k460, SafeNet KeySecure k250, SafeNet KeySecure k150v Thales EMS 200 | |
Management | ||
Management interface | Browser-based (HTML 5)
Client application
|
|
Federation | Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection. Federate like or unlike arrays, all SC models supported. | |
Scripting support | Microsoft PowerShell API RESTful API |
|
Host OS support | Microsoft Windows Server, Oracle Solaris, HP-UX, Oracle Linux, IBM AIX, Novell NetWare, SLES, Apple, HPTru64, VMware, Citrix XenServer, RedHat | |
Third-party application integrationt | VMware, Microsoft, IBM, OpenStack, Symantec, CommVault, Foglight, Docker | |
Coexistence with PS Series arrays | Replication in either direction Day-to-day management from a single interface Thin import: space-efficient, non-disruptive data migration from PS Series arrays |
|
Certifications | VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite, IBM VIOS Recognized, Oracle Validated Infrastructure (OVI); see Dell Storage Support Matrix for additional certifications and details | |
Reporting/alerts | Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback | |
Firmware updates | Online, non-disruptive. Firmware may be set to download automatically, with option to trigger installation manually if desired. |
|
Workload management | QoS, VVOLs | |
SC Hybrid | SCv3000 Series | SC5020 |
Physical | ||
Rack size | 3U | 3U |
Height | 13.33 cm (5.25 inches) | 13.33 cm (5.25 inches) |
Width | 44.5 cm (17.52 inches) | 44.5 cm (17.52 inches) |
Depth | 78.5 cm (30.9 inches) | 78.5 cm (30.9 inches) |
Weight at max configuration | 24.22 kg (53.4 lb) | 24.22 kg (53.4 lb) |
Weight empty | 15.15 kg (33.4 lb) | 15.15 kg (33.4 lb) |
Rack support | ReadyRails II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes, or tooled mounting in 4-post threaded-hole racks | |
Power | ||
Power/wattage | 2 hot-swappable power supplies (1378W or 1485W options available, wattage type not interchangeable after point of sale) | 2 hot-swappable 1485W power supplies |
Maximum output power | 1378 W (1378W supply option) or 1485 W (1485W supply option) | 1485 W |
Maximum input power | 1584 W (1378W supply option) or 1688 W (1485W supply option) | 1688 W |
Maximum input current | 16 A (1378W supply option) or 8.8 A (1485W supply option) | 8.8 A |
Maximum inrush current | 55A for 10 ms or less | 55A for 10 ms or less |
Nominal input voltage operating range | 100-240 VAC (1378W supply option) or 200-240 VAC (1485W supply option) | 200-240 VAC |
Nominal input frequency | 50/60 Hz | 50/60 Hz |
Thermal output/heat dissipation (maximum) | 5,770 BTU per hour (1378W supply option) or 5,760 BTU per hour (1485W supply option) | 5,760 BTU per hour |
Environmental Operating Conditions | ||
Operating temperature | 50 – 95°F (10 – 35°C) | |
Non-operating temperature | -40 – 149°F (-40 – 65°C) | |
Operating humidity ranges (non-condensing) | 10% to 80% with 29°C (84.2°F) maximum dew point | |
Non-operating humidity (noncondensing) | 5% to 95% with 33°C (91°F) maximum dew point | |
Inlet type | NEMA 5-15/CS22.2, n°42 | |
Services, Warranties | ||
Services | Dell ProSupport with deployment and consulting services. Optional ProSupport Plus is available offering proactive and preventative services to improve performance and stability. Dell Optimize is available for additional ongoing strategic counsel and guidance from a highly trained system analyst. | |
Diagnostics engine | Integrated Dell Remote Access Controller (iDRAC) | |
System sizing | Dell EMC Live Optics | |
Drive warranty | All SSDs are warrantied for full lifetime wear-out replacement with valid service agreement. SSD warranty covers all formats: SLC, MLC an d TLC |
Chưa có đánh giá nào.